The
Type 790 Flowmeter is based on the variable
area principle, with some models using the
guided float system.
The flow rate is indicated by the
position of the top of the float against the
scale on the tube. In addition to the visual
readout, this flowmeter may be fitted with
minimum and maximum limit switches, or a
transmitter.
Accuracy Class :
4 according to VDE/VDI 3513 Sheet 2 e.g.
1 % of end value + 3 % of indicated flow
inaccuracy in l/hr resp. m³/hr.
Electrical Accessories :
Insure that the float is the type with a
built-in magnet before fitting electrical
accessories, otherwise they cannot be
actuated. The contact 024.86.06 has a
closure with a lowering float (Min. flow) or
a closure with a rising float (Max. flow).
The contacts are adjustable over the
complete range. See also the special data
sheet.
Valves :
When measuring liquids, valves may be
installed before or after the Flow Sensor.
For gases, valves must always be mounted
after it. Valves should always be opened
slowly to prevent unnecessarily
accelerating the float against the float
rest.
Installation :
The Flow Sensor must be mounted with the
flow tube axis vertical, with the media
flowing upwards. Insure there are no undue
stresses acting upon it.
Pipe size reductions or enlargements before
or after the flowmeter do not normally cause
serious errors, it is preferable, however,
to install the Flow Sensor in a straight
length of pipe. |